100 kW Hydrogen Fuel Cell Generator

PEM fuel-cell power. Liquid-hydrogen storage. 800 V nominal DC output. Site electrical, air, cooling and vent connections required.

CELL 100 hardware preorder · Estimated dispatch 2026-12-21–2026-12-29. Ordering terms

Product features
Maximum normal gross stack output
100 kW
Electrical interface
800 VDC nominal · 150 A maximum
Hydrogen inventory
23.3 kg · 51.4 lb LH₂
Tank geometric volume
346 L · 91.4 US gal
Diameter × height
24 in × 15 ft
Equipment footprint
3.14 ft² · 0.292 m²
Fuel-cell module
Replaceable commercial PEM
Refill service
10 years, optional

Individual ownership includes a compressor. PEM system, Dewar tank, hydrogen conditioning, power electronics, cooling loop and controls included.

Gross stack power is before auxiliary loads. AC loads require site power conversion. The footprint excludes service access and site utilities.

Connections & cooling
  • Four-pin mechanical dock; blind-mate DC, protective earth, 24 VDC control power, supplier CAN and hardwired safety interfaces.
  • Dedicated cryogenic fill connection and outdoor hydrogen relief and purge discharge.
  • Two 4 in air connections: supply and exhaust. Air requirement: 6,500 NL/min at 0°C and 1 atm.
  • Two 1.25 in coolant quick disconnects. Coolant flow: 200 L/min · 52.8 US gal/min. Stack heat rejection: 115 kW.
Fuel system & protection
  • Vacuum-insulated 304L stainless-steel Dewar. Maximum envelope: 22 in diameter × 7 ft 9 in length; maximum liquid fill: 95% of tank volume.
  • Pumped liquid withdrawal, printed-circuit heat exchange, vaporization and pressure regulation before the PEM stack.
  • Continuous capacitive level sensing; independent high-fill and low-liquid switches; pressure and temperature monitoring.
  • Hydrogen detection, emergency stop, dock verification, high-voltage interlocks and insulation monitoring.
  • Two series fail-closed fuel valves. Safety trips isolate fuel, open high-voltage contactors, disable conversion and require manual reset.
  • Controlled pressure-management heater, independent hardwired high-pressure cutout and software limit; dedicated pressure and trapped-liquid relief.
  • Stack service requires electrical and fuel isolation, verified purge, lockout and controlled commissioning.

1 CELL · 100 kW

Deployment100 kW
1CELL
Output per CELL
Ownership & service

Service optionsOptional
Modern building · 360°
Preparing your site view…
Drag to look around · + / − zoom
Building setting

Actual CELL geometry in an illustrative photographic setting.

Equipment footprint
3.14 ft²
CELL 100 bodies only; pads, access space and installation clearances are additional.
Water recovery estimate
309 US gal/day
CELL 100 basis: continuous 100 kW per unit with refill and 55% LHV efficiency. Reaction estimate; actual recovery depends on condensation and collection.

Totals use the full selected quantity, not the visual sample. Other outputs are site-specific.

1 CELL selected. CELL 100 · 4.572 m × Ø 0.6096 m. Illustrative placement, not an installed ZAZA site.

Modern Buildings 2 · Alexander Scholten / CC0

Refill purchased separately.

Up to 1.2 GW

CELL purchase$200,000Estimated 3-month CELL delivery
Reservation deposit · Refundable until signing$5,000

$5,000 reservation deposit · Refundable until signing

Deposit terms

CELL Power & Service Agreement

Loading secure payment options…

Need a project review? Discuss your project

Compare CELL models

Choose 20, 30, 50, 80 or 100 kW per CELL. Hardware prices exclude hydrogen fuel, optional refill service and site installation.

Delivery & commissioning target: 2027-01-303-month schedule · New orders as of 2026-10-30 · Ordering terms

Available for preorder. Estimated three-month delivery and commissioning, including freight; delivery and site requirements are recorded in the final agreement. A $5,000 reservation deposit is credited toward that agreement and refundable until signing.

Before choosing a hydrogen fuel-cell generator

Does CELL generate electricity or hydrogen?

CELL generates electricity from supplied hydrogen using a PEM fuel cell. It is not a hydrogen gas generator or electrolyzer. Liquid hydrogen supplies the system; fuel, refill service and site installation are separate from hardware.

What emissions does CELL produce during operation?

CELL has no direct CO₂ emissions during hydrogen fuel-cell operation. Hydrogen production and delivery have separate impacts, so this is not a guarantee of zero lifecycle emissions. Site electrical, air, cooling and vent connections are required.

Can CELL power AC equipment?

CELL 100 has an 800 V nominal DC interface and 100 kW gross stack output. AC loads require site power conversion; delivered output accounts for conversion and site loads. Electrical interfaces for other CELL models must be confirmed separately.

How is a fuel cell different from a battery?

A battery stores energy for later use. A fuel cell generates electricity from supplied fuel. Plan hydrogen supply and refill logistics alongside the power demand and operating hours.

Can CELL provide backup or off-grid power?

Backup power, off-grid power and decentralized power generation require project-specific engineering and a hydrogen fuel plan. Review load profiles, site integration and operating requirements with ZAZA. Confirm required certifications, load response, site integration and hydrogen logistics for your project.

Read the buyer brief or discuss your site before selecting a model.

New CELL 100 orders estimated as of 2026-10-30: dispatch 2026-12-21–2026-12-29; arrival 2027-01-06–2027-01-28. These are planning estimates, not guaranteed dates. Freight is included within the approximately three-month overall schedule. Commissioning and final project dates are confirmed in the signed agreement.

Discuss your CELL project

Tell us what you need to power. We’ll review the configuration and site requirements. No deposit required. Project terms confirmed separately.

Modern building · 360°

Fixed capture point · Drag to look around · + / − zoom

1 CELL selected. Illustrative photographic setting; not engineered siting.