CELL.
Zero Emission Power.

Applications
- Computing & AI
- Data centers · GPU clusters · AI training & inference · edge computing · server farms · crypto mining
- Industry & manufacturing
- Industrial parks · semiconductor & pharmaceutical facilities · mining · mineral processing · oil & gas sites · cold storage
- Agriculture
- Indoor farms · greenhouses · ranches · agricultural processing
- Buildings & residential
- Commercial buildings · residential developments · estates · off-grid homes · remote properties & islands
- Telecommunications
- Telecom towers · remote communications · network facilities
- Transport & maritime
- Airports · vertiports · drone facilities · ports · shore-side & offshore facilities
- Construction & events
- Construction sites · temporary infrastructure · live events · film & broadcasting
- Power networks
- Utilities · microgrids · independent power producers · distributed energy projects
- Research & healthcare
- Universities · research laboratories · advanced computing · hospitals · medical campuses
- Resilience & defense
- Emergency response · disaster recovery · humanitarian sites · remote defense facilities
- Partners
- Equipment distributors · system integrators · energy service companies · developers · infrastructure investors
The IEA projects data-center electricity use will roughly double from 2025 to 2030. Slow grid connections are also pushing US developers toward on-site generation.
Data-center power without diesel exhaust.
Diesel should no longer be the default. Replacing it is the mission: CELL’s modular design lets customers add power one unit at a time. Diesel exhaust is a public-health issue. IARC classifies diesel engine exhaust as carcinogenic to humans. EPA links exposure to asthma, worsened heart and lung disease, and premature death. Washington’s Department of Ecology identifies diesel particles and nitrogen dioxide from data-center backup generators as health concerns. CELL offers a way to replace diesel generation with hydrogen fuel cells, removing combustion exhaust from the point of use while producing electricity, heat and water.
Power cabins, lighting and equipment on construction sites; support events, broadcasting and temporary charging; add backup and capacity for data centers. Choose a configuration around peak load, operating hours and fuel access, then move it as the project moves.
Problem
As a PEM fuel-cell plant grows, its hydrogen supply, cooling and electrical equipment must grow with it.
Design
PEM fuel-cell plants built like a server rack. Instead of one 30 MW unit, 300 × 100 kW CELLs provide 30 MW of gross stack capacity. CELL combines commercial PEM fuel cells and Dewar liquid-hydrogen storage. Add modules as demand grows, with site equipment sized for the project. Construction, industry and remote sites can use smaller configurations.
For data-center backup, UPS batteries bridge the changeover while fuel cells provide longer-duration generation with a continued hydrogen supply. CELL’s site design includes power conversion, cooling and hydrogen venting. ZAZA’s power-and-service agreement specifies 99.99% system availability, with credits or refunds for qualifying downtime. Reserve or replacement CELLs can maintain capacity during servicing.
PEM fuel cells powered NASA’s Gemini spacecraft. CELL’s aerospace design combines a carbon-fiber frame, titanium docking pins and vacuum-insulated liquid-hydrogen storage. It is designed for 6 g lateral loading and operation at altitudes up to 10,000 feet. The design references NASA GEVS for random vibration and NASA standards for shock response.
CELL is designed for vertical or horizontal transport. Its blind-mate dock groups DC power, grounding, controls, monitoring and safety connections, with mating air couplings. Fewer individual connections simplify setup and removal for servicing or relocation; coolant and hydrogen filling use separate quick-disconnects.
3 month lead. 10 minute setup.
Once the dock and site connections are ready, CELL’s controller runs startup and purges the hydrogen circuit before supplying power. Monitoring, emergency stop and reset connect to the site controls.
A dedicated cryogenic receptacle connects CELL to delivery-side hydrogen transfer equipment. 10 min Refill. 23.3 kg LH₂. Already-cold tank. Warm-tank cooldown and site setup are separate.
Optional IO refill service is planned around the project’s fuel demand and delivery access. The power-and-service agreement covers hydrogen delivery, refill, maintenance and replacement support. Customers provide site access for scheduled deliveries and service.
The PEM fuel-cell stack is replaceable, like a car engine: replace the power-producing component rather than the whole CELL.
CELL’s design specifies hydrogen detection, fail-closed fuel valves and shutdown of fuel and high voltage on a safety trip. Design requirements include ASME VIII-1 for pressure vessels, ASME B31.12 for hydrogen piping and applicable NFPA 2 and 70 provisions.
Hydrogen relief and purge gas use a dedicated outdoor vent, separate from the fuel cell’s air exhaust. Site planning must account for vent location and height, heat, noise and operating controls, subjects covered in CGA G-5.5’s 2026 update.
Hydrogen fuel cells combine hydrogen with oxygen from the air to generate electricity, heat and water without combustion. Replacing diesel generation removes that generator’s exhaust and direct CO₂ emissions from the site. Fossil fuels supplied about 58% of U.S. utility-scale electricity in 2025; the local grid mix varies.
At continuous 100 kW, 55% LHV efficiency and continued refilling, CELL 100’s reaction-water output is about 1,170 litres (309 US gallons) per day. Recovery requires condensation and collection; reuse depends on treatment and measured water quality.
Liquid hydrogen.
Electrical power.
Follow hydrogen through storage, conditioning and the PEM reaction.
What happens here

Technical details
One integrated module.
Storage, hydrogen conditioning, PEM stack, power electronics and interfaces.
- Gross stack output
- 100 kW
- LH₂ inventory
- 23.3 kg
- Outside diameter
- 24 in / 610 mm
Component housings and internal routing are schematic; dimensions and operating requirements follow the CELL 100 Specifications & Safety Standards (PDF). The enlarged PEM reaction illustrates the operating principle.
NERC describes some large-load grid connections taking months to years, while transmission expansion can take a decade. Jupiter’s power-agreement program uses a seven-month minimum planning schedule, with delivery dates set by agreement. Project delivery includes permitting and required utility coordination. Modular racks support phased expansion alongside the site’s hydrogen, cooling and venting equipment.
EIA reports average U.S. electricity prices of $90.90/MWh for industrial customers and $140.40/MWh for commercial customers for January–August 2026. Your tariff and connection costs depend on the site. Wholesale prices can swing with fuel costs, weather and demand. Retail tariffs usually smooth those swings, but can change. A fixed-price PPA can lock the contracted power rate; the agreement defines covered costs.
For a diesel example, a 100 kW Cat XQ125 at full 60 Hz load uses 6.4 US gallons an hour. At EIA’s November 9, 2026 U.S. on-highway price of $6.127/gallon, including taxes, that is about $392/MWh in fuel alone, before equipment and service. Delivered or off-road fuel prices differ. At that full-load operating point, EIA’s diesel combustion factor of 10.19 kg CO₂ per gallon puts direct emissions at about 652 kg CO₂ per MWh. Hydrogen fuel cells produce no CO₂ at the point of use.
Lazard’s July 2026 study puts unsubsidized storage cost at $210–$292/MWh for a 100 MW, four-hour battery, assuming 350 cycles a year and an initial $40/MWh charging price. This is a utility-scale storage benchmark, not continuous generation.
At 55% LHV design stack efficiency, each $1/kg of delivered hydrogen adds about $55/MWh in fuel cost at gross stack output, before auxiliary loads, electrical conversion, equipment and maintenance. This uses hydrogen’s 33.3 kWh/kg energy content.
Compare the complete project cost: power or fuel, connection works, installation, site equipment and maintenance. Each offer covers a different scope.
Order a 20–100 kW CELL with optional 10-year LH₂ refill, or choose a 10-year power purchase agreement at 19¢/kWh ($190/MWh) for projects from 20 MW.
International delivery is quoted by project. Review the CELL 100 specifications or discuss your site to plan power, fuel and installation together.
ZAZA sells CELLs and contracted MW. Jupiter is the initiative to scale hydrogen power. IO is the planned Vertical Hydrogen Power Facility: offshore generation, purification, electrolysis, LH₂ and logistics. ZAZA will pursue hydrogen pipelines for larger projects.
Infrastructure as a living system
Imagine Earth as one body. Its cities, industries and ecosystems depend on energy and water moving between them. Jupiter is our vision for an evolutionary adaptation: a new organ network that makes and delivers power where the body needs it. Nanobots for Earth, at infrastructure scale.
IO is the organ. Imagine a body reclaiming dead skin cells and turning their materials into something useful. IO’s parallel is taking otherwise-unused water, purifying it and using electricity to produce hydrogen. The water supplies the hydrogen; electricity supplies the energy. A resource outside the useful flow becomes part of it.
CELLs are the protein-like modules sent to do specific work. Hydrogen is their energy carrier, delivered in concentrated packets. Together, they bring power directly to the parts of the system drawing more energy: a growing data center, a construction site or a remote community. Like a body directing resources to an active muscle, the network adds capacity where demand grows.
In this vision, production follows demand. Hydrogen is made for the places that need power, and CELLs can move as those needs change. When less fuel is needed, water purification can continue serving other uses. Compact, vertical facilities and portable modules fit new capability into the existing system.
The renewal is as important as the energy. Picture an organ sending out both fuel and the means to repair, like stem cells arriving where tissue needs renewal. Jupiter connects that idea to cleaner local air, purified water at IO and water produced when CELLs use hydrogen. The nanobots are the image of targeted delivery; the stem cells are the image of renewal. The goal is infrastructure that helps the whole system thrive while supplying the energy it needs to grow.
Environmental scale of a CELL network
12.85M kg of hydrogen per month could fuel approximately 3,272 CELL 100 units at 100 kW gross continuously for 30 days. This uses a design fuel rate of 5.455 kg H₂/hour per unit, before production, storage and delivery losses. The table separates hydrogen production from on-site CELL operation.
| Metric | Volume | Natural Equivalent | Additional Equivalents |
|---|---|---|---|
| H₂ supply | 12.85M kg/month | From 30.35M US gal of reaction feedwater | 235.6 GWh gross electricity; 3,272 CELL 100 units running continuously. |
| Water purification | 30.35M US gal/month | 30.35 wetland acres’ water-storage volume† | 114.8M litres of purified reaction feedwater. |
| O₂ production | 102.0M kg/month | 10.38M benchmark trees’ monthly oxygen output* | 238M m² seagrass beds’ monthly oxygen output* |
| Fuel-cell air throughput | 1.788B kg/month** | 1.46B m³ of air at standard sea-level density** | Air processed, not demonstrated pollution removal. |
| Water production | 30.35M US gal/month | 30.35 wetland acres’ water-storage volume† | 114.8M litres of reaction water, before recovery losses. |
| Conventional hydrogen CO₂e baseline | 128.5M kg/month | 55K–70K hectares of Moso bamboo’s average monthly carbon fixation‡ | 1.542M acres of average U.S. forest’s monthly sequestration‡ |
**Air throughput converts the supplied 59.6M kg/day model to 30 days. Volume uses 1.225 kg/m³ standard sea-level density. Airflow does not measure pollutant removal.
Uses the molar mass balance: approximately 8.94 kg water and 7.94 kg oxygen per kg hydrogen. Electrolysis consumes water; fuel cells form it again. These are two ends of one cycle, not two separate water gains.
*Gross oxygen co-product: 102.0M kg matches the average monthly oxygen mass produced by 10.38 million healthy 32-foot ash trees (260 lb per tree per year divided by 12) or 238M m² of seagrass (10 litres/m²/day × 30 days, using 1.429 g/litre at 0°C and 1 atm). Oxygen-mass comparisons only, not ecosystem replacement or net environmental benefit; fuel cells consume oxygen again.
†Each monthly water volume equals the storage of 30.35 wetland acres at EPA’s 1M gallons/acre benchmark.
‡Carbon-mass scale for the conventional-hydrogen production baseline: Moso bamboo: 6–7.6 tonnes carbon/hectare/year in one regional study, converted to CO₂ by 44/12; U.S. forest: 1 tonne CO₂/acre/year. Both annual rates are divided by 12 for monthly averages. Bamboo fixation is not permanent storage.
Water volumes assume 1 kg/litre, in US gallons. Feedwater excludes treatment losses and other facility use; reaction water is not recovered or drinking-water yield. The 10 kg CO₂e/kg H₂ comparison sits within IEA’s 10–12 kg CO₂e/kg range for unabated natural-gas hydrogen.
Choose your CELL.
Share your power demand, runtime and location, or reserve your configuration.
A $5,000 reservation deposit is credited toward the final agreement and refundable until signing.
Ordering & shipping terms →Deposit & cancellation terms →Download the procurement brief →